Logging and Monitoring Design

AZ-305 AZ-305 · Design identity, governance, and monitoring solutions

By Abu Anns · Last updated 20 November 2026Exam version: AZ-305 (skills measured as of 17 April 2026)

You cannot operate what you cannot see. Monitoring design for AZ-305 is about building an observability platform: collecting the right telemetry from every layer, routing it to the right store, and turning it into alerts and dashboards that humans can act on. The exam tests the Azure Monitor data platform in depth — workspaces, diagnostic settings, data collection rules, alert types — and expects you to design for scale, cost, and retention requirements.

Azure Monitor and the Log Analytics workspace

Azure Monitor is the platform; the Log Analytics workspace is where log data is stored and queried with Kusto Query Language (KQL). Metrics (numerical time-series values like CPU percentage) live in the metrics database and are retained for 93 days; logs (text records like events and traces) live in the workspace with configurable retention — the default is 90 days, extendable to years, with archive options for long-term retention at lower cost. Workspace design is a real architectural decision: a single central workspace simplifies querying and alerting across the estate, while multiple workspaces can isolate data by region, compliance boundary, or billing. Microsoft's general guidance favours centralisation unless a concrete requirement (data residency, chargeback, or a regulatory boundary) forces separation. Data collection rules (DCRs) define what the Azure Monitor Agent collects from VMs and which workspace it goes to — one DCR can target many machines, and different DCRs can send different data to different workspaces. The legacy Log Analytics agent is retired, so all new designs use the Azure Monitor Agent.

Diagnostic settings: routing platform logs

Azure resources emit platform logs — resource logs (operations within the resource), activity logs (control-plane operations on the resource), and metrics. By default these logs go nowhere permanent; diagnostic settings route them to a Log Analytics workspace, a storage account, or an event hub. Design rules: send logs to a workspace for querying and alerting; send to a storage account for cheap long-term archival (often with lifecycle management to cool/archive tiers); send to an event hub when a third-party SIEM or streaming pipeline consumes them. Use Azure Policy (DeployIfNotExists) to ensure diagnostic settings are enabled on every resource of a given type — manual configuration does not scale. Note that diagnostic settings are per-resource, so the policy approach is the only reliable way to guarantee coverage. For cost control, be selective about log categories: enabling every category on every resource is the fastest way to an enormous Log Analytics bill.

Application Insights and distributed tracing

Application Insights (now workspace-based, storing data in a Log Analytics workspace) monitors live applications: request rates, response times, failure rates, dependencies, exceptions, and custom events. It supports distributed tracing across microservices, so a slow request can be followed from the front door through each service. Design points: use sampling to control ingestion volume on high-traffic apps (adaptive sampling keeps representative data while capping cost); use availability tests (URL ping and multi-step web tests) to detect outages from outside; and use live metrics for real-time troubleshooting during incidents. When a scenario describes a microservices app with performance problems nobody can localise, Application Insights with distributed tracing is the answer.

Alerts: the right signal, the right action

Azure Monitor alerts come in types matched to the data: metric alerts fire on threshold breaches (CPU above 90 percent for five minutes); log alerts run a KQL query on a schedule and fire when the result matches a condition; activity log alerts fire on control-plane events (a VM deleted, a role assigned); resource health alerts fire when Azure reports a platform problem. Action groups define what happens when an alert fires: email, SMS, voice call, webhook, Logic App, or automation runbook. Design guidance: alert on symptoms that affect users (availability, latency, error rate) rather than on every infrastructure blip; use alert processing rules (formerly suppression rules) to silence alerts during maintenance windows; and route alerts to the team that owns the service — action groups per service, not one global group. For high-severity alerts, consider automatic remediation: an alert can trigger a Logic App or runbook that restarts a service or scales out, before a human is even paged.

Dashboards, workbooks, and SIEM

Azure dashboards pin metrics and queries for at-a-glance views; Azure Workbooks combine text, queries, parameters, and visualisations into interactive reports — ideal for operations reviews and post-incident analysis. For security monitoring at scale, Microsoft Sentinel is Azure's cloud-native SIEM: it ingests logs from Azure, Microsoft 365, and third-party sources into a Log Analytics workspace, applies analytics rules to detect threats, and orchestrates investigation and response with playbooks (Logic Apps). Sentinel is the answer when a scenario asks for centralised security event analysis, threat hunting, or automated incident response across hybrid sources. Remember its cost driver: ingestion volume — use data collection rules and filtering to ingest what matters.

Cost and retention design

Monitoring cost is dominated by log ingestion and retention. Control it by: collecting only needed log categories; using basic logs (cheaper, lower-query-performance tier) for high-volume verbose logs; setting table-level retention (different tables, different retention); archiving old data to storage; and using sampling in Application Insights. Retention requirements often come from compliance: if a regulator requires seven years of audit logs, the design is workspace retention plus archival to a storage account with immutability policies — not seven years of hot workspace retention.

Workspace strategy at scale

As an estate grows, workspace design becomes a genuine architecture decision. A single central workspace simplifies cross-resource queries, alerting, and Sentinel deployment, and it is Microsoft's general recommendation. Multiple workspaces are justified by concrete requirements: data residency (logs must stay in a specific region), chargeback (separate bills per business unit), access isolation (different teams must not see each other's logs), or retention differences (one workload needs seven years, another needs 30 days). Cross-workspace queries can join data across workspaces when centralisation is not possible, and Azure Lighthouse lets a central operations team manage monitoring across tenants. For access control, use table-level RBAC and resource-context access so teams see only their own data. A common exam trap is recommending a workspace per resource group or per application — that fragments querying and alerting and multiplies management overhead. Centralise by default, split only for a stated requirement, and document the reason.

Advertisement

Exam traps to watch for

Practice questions

Test yourself on this guide. Answers are checked instantly, with a full explanation for each question.

Q1.A company must retain Azure activity logs for seven years for regulatory compliance, but only needs to query the most recent 90 days interactively. What is the most cost-effective design?

Report an error

Q2.An operations team needs to be notified immediately when any virtual machine in the production subscription is deleted. Which alert type should the architect recommend?

Report an error

Q3.A microservices application on AKS is experiencing intermittent slow responses, but no single service shows high CPU or memory use. What should the architect recommend to find the cause?

Report an error

Q4.A company has hundreds of Azure resources and wants to guarantee that diagnostic settings are enabled on every new Key Vault and storage account. What is the most reliable approach?

Report an error

Q5.A security team wants to collect security events from Azure, Microsoft 365, and on-premises firewalls in one place, run threat-detection rules over them, and automate incident response. Which service should the architect recommend?

Report an error

Q6.A high-traffic web application generates enormous Application Insights telemetry, and the ingestion cost is now a problem. What should the architect recommend to control cost while keeping representative data?

Report an error

Q7.An operations team wants a single interactive report that combines text explanations, KQL query results, and charts for their weekly operations review. Which Azure Monitor feature should the architect recommend?

Report an error

Q8.A company runs VMs across three regions and needs to collect different log sets from production VMs than from development VMs, sending each to its own workspace. Which mechanism should the architect recommend?

Report an error

Q9.During a planned maintenance window, an on-call engineer is woken by alerts for services that are intentionally offline. What should the architect recommend to prevent this in future windows?